Knowledge Index Print this page Back Approved Document J

2010 changes

The 2010 Edition of Approved Document J continues the principles of the 2002 Edition. The main changes to the legal requirements and technical guidance are described on the inside front cover of the Approved Document [Page 2 of 89 in the Online Version]. The main changes to the technical guidance are highlighted below.

2002 Edition 2010 Edition Changes from 2002 to 2010 Edition
- 0.4 .13 : Equivalent area New paragraph in the 2010 Edition. Subsequent paragraphs renumbered (+1) compared with the 2002 Edition.
0.4 .27 : Heat input rate 0.4 .28 : Heat input rate Paragraph re-written.
0.4 .28 : Independantly certified No equivalent Paragraph omitted in the 2010 Edition. Subsequent paragraphs have the same number as the 2002 Edition.
- 0.4 .39 : Solid biofuel New paragraph in the 2010 Edition. Subsequent paragraph renumbered (+1) compared with the 2002 Edition.
- 1.1.c : carbon monoxide warning New paragraph in the 2010 Edition. Subsequent paragraphs renumbered (+1) compared with the 2002 Edition.
1.8 : Ventilation of other rooms 1.8 : Ventilation of other rooms Approved Document F revised to Approve Document C.
- 1.47 : Concealed flues
and
Diagram 14 : Example locations ...
New paragraph and related diagram in the 2010 Edition. Subsequent paragraphs renumbered (+1) compared with the 2002 Edition.
Table 2 : Size of flues in chimneys Table 2 : Size of flues in chimneys Item for pellet burner or pellet boiler added.
Diagram 17 : Flue outlet positions Diagram 17 : Flue outlet positions Clarification of requirements.
2.12 : Outlets from flues 2.12 : Outlets from flues Note on thatched roofs added.
- Table 3 : Minimum performance designations ... New table.
- 2.27 : Hearths New paragraph in the 2010 Edition. Subsequent paragraphs in Section 2 renumbered (+1) compared with the 2002 Edition.
Table 3 : Prefabricated appliance chambers Table 4 : Prefabricated appliance chambers Renumbered, but content unchanged.
- 2.34 to 2.36 : Carbon monoxide alarms New requirements in the 2010 Edition.
3.12 : Flued (DFE) fires 3.12 : Flued (DFE) fires Revised to refer to "very airtight" buildings and the new Appendix F.
Diagram 32 : Free areas of permanently open air vents ... Diagram 32 : Free areas of permanently open air vents ... Note 5, referring to older dwellings, added.
Diagram 33 : Ventilation for flueless gas appliances Diagram 33 : Ventilation for flueless gas appliances Note 8, referring to doors that open directly to the outside, added.
Table 4 : Sizes of flues for gas-fired appliances Table 5 : Sizes of flues for gas-fired appliances Renumbered, but content unchanged.
3.23 : Outlets from flues 3.23 : Outlets from flues Note added.
Table 5 : Minimum performance designations Table 6 : Minimum performance designations Renumbered, but content unchanged.
Table 6 : Protecting buildings from hot flues Table 7 : Protecting buildings from hot flues Renumbered, but content unchanged.
- - -